Product Specifications

--

Product Description

Large Power Capacity Solar Inverter with Wind Diesel Grid Function

 

Products Advantages

  • With SPWM technology controlled by CPU, pure sine wave output;
  • Reliable with dynamic current loop control technology;
  • High power IGBT module with strong power output applying to capacitive load, inductive load and nonlinear mixed load;
  • Strong overload ability, strong resists shocks ability, can start with full load;
  • Perfect protection function: input over/low voltage, overload, short circuit, low battery voltage, over temperature etc.
  • Static switching SCR switching control, zero delay conversion
  • High efficiency, low noise, smokeless, no fire hazard;
  • Automatic switch, realize unattended function;
  • Communication function: USB interface/SNMP remote control/GSM SMS function;
  • AC priority or DC priority selectable
  • Stable performance, safe and reliable, long service life.
  • 2.2 Product appearance

     (The picture is for reference, the color and appearance are according to the inverter you receive.)

     

    Products Parameters

    Model10-40KW
    Rate Power10-40KW
    Instant powerThree times
    DC InputDC voltage96V(10K);192V(10-20K);240V(30-40K)
    Battery No.12V battery: 8pcs/16pcs/20pcs
    Battery typeMaintenance-free lead-acid batteries
    AC InputPhaseSingle Phase
    Frequency50Hz ± 10%
    AC input110V(85-140V)/220V(165-275V) (L+N+G)
    AC AVR output110/220VAC (L+N+G)±10%
    ChargingFloating charge voltageDC96V:116V/DC192V:232V/DC240V:280V
    Overcharge protect voltageDC96V:124V/DC192V:248V/240V:310V
    Charge current10-20A adjustable ( Charging current can be customized )
    Invert outputOutput voltage110V/220VAC (L+N+G)±1%
    Frequency50Hz ± 0.1%
    THD≤ 3% (Linear load)
    Dynamic response5% (0%~100% load)
    Crest factor3:1
    Invert efficiency97%
    AlarmBuzzing and LCD screen flicker
    Protection functionAc overvoltage, under voltage, DC overvoltage, under voltage, Overload, Output short circuit
    Overload capacity>100-120% alarm 60s then shutdown;
    >100-120%, back to normal working when cut down loads during alarm 60s;
    >150% Instant shutdown
    Communication interfaceUSB/RS232/SNMP(option)
    Protection classIP21
    Surge handling capability10/700US,5KVA;8/20US,20KA
    Noise dB≤45db
    Cooling modeForced ventilation
    Ambient Temperature Temperature 0-40ºC, relative humidity 10%-90%, elevation<1000m
     

    Technical data of MPPT solar charger controller

     

    Rated voltage96V
    Rated current100A
    Maximum protection current104A
    Battery voltage identification rangeDC72-120V
    MPPT Operating voltage rangeDC130-DC180V
    PV input low voltage protection pointDC120V
    PV input low pressure recovery pointDC130V
    Maximum PV input power13600W
    Limit input voltageDC225V
    PV input overvoltage protection pointDC230V
    PV input overvoltage recovery pointDC225V
    charging method3 stage constant current(MPPT),equalizing charge, float charge
    System type96V Automatic identify (72V manual setting)
    Static power consumption4W
    Machine efficiency96.5%
    PV module utilization99.97%
    Float voltage (can be customized)DC110V
    Average charge voltage(can be customized)DC113.6V
    Recommended PV module voltage144V-180V
    Temperature compensation-3mV°C/2V
    Temperature protection+85°C
    Temperature rise protection85°C or more to reduce power output
    Protective functionPV array short circuit overvoltage, overcurrent reverse polarity protection,
    battery overcharge, reverse protection, Under voltage protection
    Working temperature-10°C~+45°C
    Humidity0~90%RH (Not condensation)
    Altitude0~3000m
    Security LevelCE, PSE, FCC, EMC
    Mechanical protection classIP21
    Optional battery typeLead-acid battery, colloidal batteries, liquid batteries, lithium batteries (Also can be customized for other types of battery charging)

    2.6 Protection

    Inverter has perfect protection function. Once appear faults, inverter will switch to invert mode or stop output, to protect itself and protect the load.

     

    Protect functionStatusProtective actionRecovery
    AC input overvoltage or undervoltageVoltage above or below the setting valueSwitch to invert output automaticallyAfter troubleshooting, inverter will automatically return to normal working condition.
    DC input overvoltage or undervoltageVoltage above or below the setting valueStop output
    Over-temperatureInternal working temperature is too highAC input state: buzzing; DC input state: buzzing and stop outputRule out the reasons leading to high temperature, inverter will work normal.
    Output overloadload power is bigger than the rated powerAC input mode: alarm and screen flicker;
    DC input mode: alarm and stop output
    After troubleshooting, need to restart the inverter to back to normal working condition.

    When AC input undervoltage,inverter will automatically restart when the voltage is restored to above the protection setting value. If input voltage is between low voltage protection value and low voltage recovery value, inverter will stay in invert state and continue buzzing.

    2.7 Operation environment

    You should bear in mind the following points when positioning the inverter:

    Place: No dust, no direct sunlight, dry, spacious ventilation

    Keep away from the corrosive gas and liquid

    Keep away from fire

    Keep away from inflammable and explosive articles

    Connection to safety power supply

    Environment temperature: 0ºC~40ºC

    Relative environment humidity: 10%~90% non-condensing

    Payment Terms

     

    Payment TermsT/TEXW30% T/T in advance, paid the balance before shipment
    FOB
    CFR(C&F)30% T/T in advance, paid the balance against copy of B/L
    CIF
    L/CL/C amount above 50,000 usd, we can accept L/C at sight
    West UnionAmount lower than 5000usd
    Paypal
    Delivery time10 working days after receiving payment for one container

     

     

    FAQ

    Q1: How to choose a right inverter?

    A1:Tell us your demand, then our sales will recommend a suitable inverter to you.

     Q2: What's the different between inverter and solar inverter?

    A2:  Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.  

     Q3: How about the delivery time?

    A3:  7 days for sample; 25 days for bulk order.

     Q4: What is the warranty of inverter?

    A4: One year warranty on FGET-Solar product.

     Q5: How to solve the technical problem?

    A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.

    Supply Ability

    --

    Packaging and Shipping

    Lead time

    --

    Port

    --

    Packaging details

    --


    Comments
    Welcome to zddshop comments! Please keep conversations courteous and on-topic. To fosterproductive and respectful conversations, you may see comments from our Community Managers.
    Sign up to post
    Sort by
    Show More Comments

    Other offers of this wholesaler

    Copyright 2023-2025 - www.zddshop.com All Rights Reserved