Function Features:
- MPPT charge controller, make full use of solar panels;
- Three-stage charging(constant current, constant voltage,float charge), it extends the batteries life;
- With functions of power generating record, Event record,Time switch, Auto sleep function;
-Users can set up PV priority or grid power priority
-Pure sine wave output & complete protection;
-Low frequency circuit design, good system reliability, low breakdown rates and long lifespan;
-High ability of anti-attack from the loads;
-With AC/Diesel input interface(Optional)
-AC charger function (Optional)
Model | RSA220-10KVA3 | RSA220-15KVA3 | RSA220-20KVA3 | RSA220-30KVA3 | RSA220-40KVA3 | |||||||||
Rated Output Power(KVA) | 10 | 15 | 20 | 30 | 40 | |||||||||
Battery | ||||||||||||||
Rated Voltage(VDC) | 220.0 | |||||||||||||
Floating Voltage(VDC) | Adjustable | 243.0 | ||||||||||||
Bulk Charge Voltage(VDC) | 255.6 | |||||||||||||
Solar Input | ||||||||||||||
Controller Type | MPPT | |||||||||||||
Maximum Input Power(KWP) | 14 | 26 | ||||||||||||
Maximum Charge Current(A) | 50 | 100 | ||||||||||||
Start Voltage(VDC) | 270 | |||||||||||||
MPPT Voltage Range(VDC) | 260-450 | |||||||||||||
/Maximum Open Circuit Voltage(VDC) | 480 | |||||||||||||
AC Bypass(Optional) | ||||||||||||||
Allowable Input Voltage Range(VDC) | 380±15% | |||||||||||||
Input Frequency(HZ) | 50/60±3% | |||||||||||||
AC Charger | Optional | |||||||||||||
AC Output | ||||||||||||||
Output Waveform | Pure Sine Wave | |||||||||||||
Output Voltage | 380VAC±1% | |||||||||||||
Output Frequency | 50/60±1% | |||||||||||||
Output waveform distortion rate (THD) | ≤3%(Liner load) | |||||||||||||
Inverter Efficiency (80% resistive load) | ≥90% | |||||||||||||
Current Peak Factor | 3:1 | |||||||||||||
Overload Ability | 105-110%,600Seconds;110-125%,60Seconds;>125%,1Second | |||||||||||||
Display Method | LCD+LED | |||||||||||||
Protection | Input reverse protection; Input low voltage protection; Input over voltage protection; Output overload protection; Output short circuit protection(do not recovery automatically need to restart machine); Machine over heating protection. | |||||||||||||
Communication Function | RS485(Optional) | |||||||||||||
Environment | ||||||||||||||
Protective Level | IP20 | |||||||||||||
Applied Altitude(M) | ≤4000(above 100meters,rated power derating every 100meters) | |||||||||||||
Cooling Method | Force Cooling | |||||||||||||
Allowable relative humidity | <95% Non-condensation | |||||||||||||
Environment Temperature(ºC) | -10~+50 | |||||||||||||
Noise(1Meter) | ≤60dB | |||||||||||||
Volume & Weight | ||||||||||||||
D*W*H(mm) | 840*480*1230 | 600*800*1600 | ||||||||||||
Weight(KG) | 230 | 250 | 300 | 350 | 460 |