Overview

Quick Details

Condition: New

Warranty: 1 Year

Applicable Industries: Manufacturing Plant, Home Use, Retail, Energy & Mining

Showroom Location: None

Video outgoing-inspection: Not Available

Machinery Test Report: Not Available

Marketing Type: New Product 2020

Warranty of core components: 1 Year

Core Components: Pressure vessel

Place of Origin: China

Brand Name: CSSB,SAKO,UNITY

Model Number: 6-FM-17

Type: Plant

Electricity Generator Type: lead acid

Output Voltage (V): 12

Key Selling Points: High Productivity

Color: black

Weight: 4.8kg

Battery case: ABS

Case Size: 181*77*167mm

Capacity: 17AH

Voltage: 12V

After-sales Service Provided: Video technical support

Local Service Location: None

Supply Ability

Supply Ability: 100000 Piece/Pieces per Month

Packaging & Delivery

 

Specifications

 

battery characteristic

Nominal voltage

12V

Nominal capacity(20h rate)

17Ah

Size

Total height

167mm

length

181mm

width

76mm

height

167mm

Weight

5.1kg

Rated  capacity   25°C(77°F)

20 hour rate(0.85A)

17Ah

10 hour rate(1.56A)

16.5Ah

5 hour rate(2.90A)

15.6Ah

1 hour rate(10.2A)

10.8Ah

Internal resistance

in full charge status 25°C(77°F)

17mΩ

Capacity at different temperature(10h)

40°C(104°F)

102%

25°C(77°F)

100%

0°C(32°F)

85%

-15°C(5°F)

65%

Self discharge     25°C(77°F)

capacity after 3 months

91%

capacity after 6 months

82%

capacity after 12 months

64%

Mode of charge (constant voltage)       25°C(77°F)

cycle-use

initial charging current less than5.40A ,                    voltage14.10-14.40V

float-use

Initial charging current less than 2.55A voltage13.50-13.80V

 12V17Ah valve regulated lead acid battery UPS from China supplier

 

1.Low self-discharge:At theambient temperature 250C,the rate of self-discharge less than 1.8% after 28 days storage.

2.Wide operating temperature range:Shensong battery can charge by 0~400C ,discharge by -20~+550C and store by-15~+500C. 

3.Good sealing capability:No pollution and corrosion, which ensures Shensong battery operate sately and efficiently in side and vertical position.The sealed construction can combine the generated gas to water,and noneed to add water or check their specific gravity during the life of Shensong batteries.

4.Good electric conductivity:Adopting red copper with silver plated patent terminal canmake batteries discharge with high current.

 12V17Ah valve regulated lead acid battery UPS from China supplier12V17Ah valve regulated lead acid battery UPS from China supplier

 

Notice

 

1. According to the requirement of application and design to choose battery model,characteristics and mounting method.

 

2. Avoid mixing use of the batteries with different capacity,manufacturers,characteristics and models.

 

3. It is recommended to charge the battery using the method of constant voltage-limited current.Under the ambient temperature 25 ℃

:for standby use,the charging voltage is2.23-2.30V/cell,and no limit on the maximum current;for cycle use, the charging voltage is 2.40-2.50V/cell,average charging voltage:2.35-2.4V/cell.The maximum current is 0.3C10(C10 is the rated capacity of discharging at 10 hours rate).

 

4. During operating,please sdjust the battery charging voltage according to the ambient temperature. The temperature compensation coefficient is -3mV/℃ cell for standby use ,i.e. the temperature increases 1 ℃

,the charging voltage decreases 3mV/cell.The temperature compensation coefficient is -5mV/ ℃cell for cycle use;average charging time:-4mV/ ℃cell.

 

5. Do not charge the battery in a sealed container or in upside down position.It is recommended to charge thebattery in a well ventilated place.

 

6. Do not charge the battery near a heater,or the place where heat accumulation may occur.Do not charge the battery in a place where there is direct sunshine.

 

7. Never have the batteries deposited with organic solvents to prevent the container from being out of shape or corrosion.

 

8. Battery should never be stored in a discharge state for a long period of time ,please recharge the battery after discharge to keep the capacity.During operating,do not over discharge to avoid the plates severe sulphation which affects the service life and capacity.

 

9. Do not over charge the battery ,as the safety vent opens constantly,which will cause the loss of water,finally shorten the service life of battery.

 

10. Red color stand for positive,and black for negative.Please connect the pole of batteries correctly.

 

11. keep the whole battery clean and connection strong.Avoid the damage due to the loose connection.

 

12. Do not disassemble or throw the battery into fire,against the explosion.

 

Supply Ability

--

Packaging and Shipping

Lead time

--

Port

--

Packaging details

--


Comments
Welcome to zddshop comments! Please keep conversations courteous and on-topic. To fosterproductive and respectful conversations, you may see comments from our Community Managers.
Sign up to post
Sort by
Show More Comments

Other offers of this wholesaler

Copyright 2023-2025 - www.zddshop.com All Rights Reserved