48V 30A Solar Panel Charger Battery Controller for solar system with Light and Timer Control CM3048
30A 48V
CM series controller is a kind of intelligent and multifunctional solar charge controller. These serial products adopt customized LCD display screen, which makes the operation on the interface rather convenient. All the controlling parameters can be reset flexibly to satisfy your different needs.
Specification
| Model | CM3048 |
| Rated Working Current | 30A |
| Rated Working Voltage | 48V |
| Voltage of Solar Panels | ≤70V |
| Float Charging Voltage(settable) | 55.2V |
| Low Voltage Protection(settable) | 42.8V |
| Low Voltage Recovery(settable) | 50V |
| No loadloss | ≤30mA |
| Loop Voltage Drop | ≤170mV |
| Temperature Compensation | -4mV/Cell/ºC |
| Installable Maximum Cable | 7#AWG(16mm2) |
| Working Temperature | -10ºC~60ºC |
| Storage Temperature | -30ºC~70ºC |
| Temperature Requirement | ≤90%,no condensation |
| Distance of Installation holes | 60mm*178mm--Ф5 |
| Temperature Requirement | ≤90%,no condensation |
Main Features
1)Visual LCD graphic symbol
2)Brief key operation
3)Grade auto switch of system voltage
4)Intelligent PWM Charging Mode
5)Auto temperature compensation
6)Adjustable charging & discharging parameter
7)Settable working modes of loads
8)Accumulative function of charging & discharging AH
9)Remote Monitoring Function
10)Protection for battery back discharging
11)Protection for battery low voltage
12)Overloading & short-circuit protection
13)Battery reversed protection
14)Delayed auto restart after overloading protection
Application Method
| System | 48V |
| Max PV Input Power | 1440W |
| Max PV Input Voltage | 72V |
| Battery Voltage | 48V |
| Load Output Current | 30A |
Attentio
Connection Order:
1.Connect the battery with the controller.
2.Connect the solar panel with the controller.
3.Connect the load with the controller or inverter.
Disconnection order:
1.Disconnect the solar panel.
2.Disconnect the battery.
3.Disconnect the load.
Precautions:
1.please make sure connect your inverter with your battery
2.Please avoid to install in the following environments wet,dusty places or places with flammable and explosive gases.
3.Install the controller at the vertical plane.
Instructions
1. Ready tools and cables. Encourage you to matching the right cables. Ensure that the current density<4mm2 that is conductive to reducing the line voltage drop. Recommended: 60A with 20mm2 cable. Check weather the installation sitescompliance with the relevant safety requirements. Please avoid the damp, dusty, there is a place flammable, explosive and corrosive gases use the controller to install.
2. Install the controller into a fixed vertical plane. See section 5 of the pore size and pore spacing. In order to ensure a good thermal control conditions, please set aside each 10cm below the controller space.
3. As shown on the right, connect the (1) Load, (2) Battery and (3) Solar Panel to the controller according to the order of (1) (2) (3). Pay attention to the load, battery, solar panel and controller of same polarity.
4. Put into the external temperature sensor on the left of the controller (probe port). The temperature sensor should be similar space with battery. (Otherwise, the controller will control the parameters of all wrong temperature compensation.)
5.If you have remote monitoring and control function, please insert one end of the included communication wire on the right of the controller (communication port), the other end to connect to The host computer.
Demolition: To prevent accidents, please order the demolition of solar panels, battery and load disconnect with controller.