zddshop
/
Product
/
Energy
/
Best Inverter 12kw 48V DC 110V/220VAC off Grid Best Solar Power Inverter with Auto Generator Starting, Battery Temperature Sensor

Best Inverter 12kw 48V DC 110V/220VAC off Grid Best Solar Power Inverter with Auto Generator Starting, Battery Temperature Sensor

$1398 /piece price excl.VAT

Negotiable
Order

Minimal order
100 pieces

Message Phone call

Product Specifications

Type

DC/AC Inverters

Product Description

Best Inverter 12KW 48V DC 110V/220VAC Off Grid Best Solar Power Inverter with Auto Generator Starting, Battery Temperature Sensor

Main Introduction

HLP Series Pure Sine Wave Inverter is a combination of an inverter, charger, solar power and Auto-transfer switch into one complete system. It is packed with unique features and it is one of the most advanced inverter/chargers in the market today.

 Key Feature

Smart Remote Control (RMT)

Battery Temperature Sensor (BTS)

Automatic Generator Starting (AGS)

Support Solar Panel with MPPT Function

Designed to Operate under Harsh Environment

DC Start & Automatic Self-Diagnostic Function

Compatible with Both Linear & Non-Linear Load

Easy to Install & Easy to Operate & Easy to Solve

Low DC Voltage Supports Home & Office Appliances

Powerful Charge Rate Up to 120Amp, Selectable From 0%-100%

High Efficiency Design & "Power Saving Mode" to Conserve Energy

Battery Priority Mode, Designates the Inverter-Preferred UPS Configuration

13 Vdc Battery Recover Point, Dedicated for Renewable Energy Systems

8 pre Set Battery Type Selector plus De-sulphation for Totally Flat Batteries

Technical specifications

Model1.0KW1.5KW2.0KW3.0KW4.0KW5.0KW6.0KW8.0KW10.0KW12.0KW
Continuous Output Power1.0KW1.5KW2.0KW3.0KW4.0KW5.0KW6.0KW8.0KW10.0KW12.0KW
Surge Rating(20ms)3.0KW4.5KW6.0KW9.0KW12.0KW15.0KW18.0KW24.0KW30.0KW36.0KW
Inverter Output
Output WaveformPure Sine wave/Same as input(Bypass Mode)
Nominal Efficiency>88%(Peak)
Line Mode Efficiency>95%
Power Factor0.9-1.0
Nominal Output Voltage rms100-110-120Vac / 220-230-240Vac
Output Voltage Regulation±10% RMS
Output Frequency50Hz ± 0.3Hz/60Hz ± 0.3Hz
Short Circuit ProtectionYes( 1sec after fault )
Typical Transfer Time10ms(Max)
THD< 10&percnt;
DC Input
Nominal Input Voltage12&period;0Vdc &sol; 24&period;0Vdc &sol; 48&period;0Vdc24&period;0Vdc &sol; 48&period;0Vdc48&period;0Vdc
Minimum Start Voltage10&period;0Vdc &sol; 10&period;5Vdc for 12Vdc Mode&ast;2 for 24Vdc&comma; &ast;4 for 48Vdc&semi;
Low Battery Alarm10&period;5Vdc &sol; 11&period;0Vdc for 12Vdc Mode
Low Battery Trip10&period;0Vdc &sol; 10&period;5Vdc for 12Vdc Mode
High Voltage Alarm16&period;0Vdc for 12Vdc Mode
Low Battery voltage recover15&period;5Vdc for 12Vdc Mode
Idle Consumption-Search Mode< 25 W when Power Saver On&period;&lpar;Refer to Table &rpar;
Charger
Output VoltageDepends on battery type &lpar;Refer to Table 2&period;5&period;2&rpar;
Charger Breaker Rating10A15A20A20A20A30A30A40A40A40A
Max Charge Power Rate1&sol;3 Rating Power &lpar;Refer to Table 2&period;5&period;3&rpar;
Battery Initial Voltage for Start 10-15&period;7Vdc for 12Vdc Mode&ast;2 for 24Vdc&comma; &ast;4 for 48Vdc&semi;
Over Charge Protection S&period;D&period;15&period;7Vdc for 12Vdc Mode
BTS
Battery Temperature Sensor&lpar;Optional&rpar; Yes&lpar;Refer to the table &rpar; Variances in Charging Voltage & S&period;D Voltage Base on the Battery Temperature&period;
Bypass & Protection
Input Voltage WaveformSine wave &lpar;Grid or Generator&rpar;
Nominal Voltage110Vac120Vac220Vac230Vac
Max Input AC Voltage150VAC For 120Vac LV Mode&semi;300VAC For 230Vac HV Mode&semi;
Nominal Input Frequency50Hz or 60Hz 
Low Freq Trip47&pm;0&period;3Hz for 50Hz&comma; 57&pm;0&period;3Hz for 60Hz
High Freq Trip55&pm;0&period;3Hz for 50Hz&comma; 65&pm;0&period;3Hz for 60Hz
Overload protection&lpar;SMPS load&rpar;Circuit Breaker
Output Short circuit protectionCircuit Breaker
Bypass breaker rating10A15A20A30A40A40A40A50A63A63A
Transfer switch rating30Amp for UL & TUV40Amp for UL80Amp for UL
Bypass without battery connectedYes &lpar;Optional&rpar;
Max bypass current30Amp40Amp80Amp
Solar Charger
Rated Voltage12Vdc &sol; 24Vdc &sol; 48Vdc
Solar Input Voltage Range15-30Vdc &sol; 30-55Vdc &sol; 55-100Vdc 
Rated Charge Current40 ~ 60A
Rated Output Current15A
Self Consumption< 10mA
Bulk Charge&lpar;Default&rpar;14&period;5Vdc for 12Vdc Mode&lpar; &ast;2 for 24Vdc&comma; &ast;4 for 48Vdc&rpar;
Floating Charge&lpar;Default&rpar;13&period;5Vdc for 12Vdc Mode
Equalization Charge&lpar;Default&rpar;14&period;0Vdc for 12Vdc Mode
Over Charge Disconnection14&period;8Vdc for 12Vdc Mode
Over Charge Recovery13&period;6Vdc for 12Vdc Mode
Over Discharge Disconnection10&period;8Vdc for 12Vdc Mode
Over Discharge Reconnection12&period;3Vdc for 12Vdc Mode
Temperature Compensation-13&period;2mV&sol;ºC for 12Vdc Mode
Ambient Temperature0 ~ 40ºC&lpar;Full load&rpar;  40 ~ 60ºC&lpar;Derating&rpar;
Mechanical Specifications 
MountingWall Mount
Inverter Dimensions&lpar;L&ast;W&ast;H&rpar;388&ast;415&ast;200mm488&ast;415&ast;200mm588&ast;415&ast;200mm
Inverter Weight&lpar;Solar Chg&rpar;KG21&plus;2&period;522&plus;2&period;523&plus;2&period;527&plus;2&period;538&plus;2&period;548&plus;2&period;549&plus;2&period;560&plus;2&period;566&plus;2&period;570&plus;2&period;5
Shipping Dimensions&lpar;L&ast;W&ast;H&rpar;550&ast;520&ast;310mm650&ast;520&ast;310mm750&ast;520&ast;310mm
Shipping Weight&lpar;Solar Charge&rpar;KG23&plus;2&period;524&plus;2&period;525&plus;2&period;529&plus;2&period;540&plus;2&period;550&plus;2&period;551&plus;2&period;562&plus;2&period;568&plus;2&period;572&plus;2&period;5
DisplayStatus LEDs &sol; Status LEDs&plus;LCD
Standard Warranty2 Years &lpar;Optional&rpar;

Supply Ability

--

Packaging and Shipping

Lead time

--

Port

--

Packaging details

--


Comments