off Grid Single Phase Solar Inverter for Solar
$698
/piece
price excl.VAT
Negotiable
- Minimal order
- 100 pieces
Message Phone call
Product Specifications
Type
DC/AC Inverters
Product Description
NP series off grid solar hybrid inverter 1KW to 6KW
Models | NP1KW | NP1.5KW | NP2KW | NP3KW | NP4KW | NP5KW | NP6KW | ||
Rated power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | ||
Battery voltage | 24V/48VDC | 24V/48V/96VDC | 48V/96VDC | ||||||
Net weight | 16Kg | 18Kg | 22Kg | 26Kg | 31Kg | 34Kg | 38Kg | ||
Gross weight | 18Kg | 20Kg | 24Kg | 28Kg | 40Kg | 43Kg | 47Kg | ||
Dimension L×W×H | 460×220×385mm | 460×260×470mm | |||||||
Package size L×W×Hm | 520×285×480mm | 520×310×540mm | |||||||
Inverter | AC input voltage range | 100/110/120/127/220/230/240VAC(+25%, -45%) | |||||||
Input frequency | 45-65Hz | ||||||||
Battery voltage range | 24VDC(20V-30V) | 48VDC(40V-60V) | 96VDC(80V-120V) | ||||||
Output voltage range | Inverter mode: 110V/220V/230V/240V±3% | ||||||||
Output frequency | 50/60±0.3Hz | ||||||||
Output waveform | Pure sine wave | ||||||||
Efficiency | 85% | 91% | 93% | ||||||
THD | <5% | ||||||||
Noise | <52dB | ||||||||
Transfer time(ms) | <5ms | ||||||||
Cold start power | Rated power 100%(resistive load) | ||||||||
Low battery voltage trip | 24VDC(20V±0.5V) | 48VDC(40V±0.5V) | 96VDC(80V±0.5V) | ||||||
Protection | A: Over-load protection; B: Battery over-charge/discharge protection; C:Over-temperature protection; D: Output voltage abnormal protection. | ||||||||
Power on/off mode | A: Turning on/off by manual, IPS will be started/closed when pressing ON/OFF button. B: When IPS is connected with battery, it will start automatically when AC comes in(no need to press ON button). | ||||||||
Beeper alarm | A: When AC works normally, no alarm with IPS. B: When at battery low voltage, beeper alarms by 1 second. C: When at over-load, beeper alarms by 1 second. D: When IPS failed at battery mode, beeper alarms continuously. | ||||||||
Solar charge controller | Rated PV input voltage | 36VDC | 72VDC | 144VDC | |||||
Maximum PV input voltage | 42VDC | 84VDC | 168VDC | ||||||
DC charge voltage | 27VDC | 54VDC | 108VDC | ||||||
PV charge current range | 30A-120A, optional(40A 1 unit, 80A 2 units, 120A 3 units) | ||||||||
Protection type | Solar cells anti-reversal charge protection, battery open circuit protection, battery reversal polarity protection. | ||||||||
Over discharge voltage trip | 20VDC | 40VDC | 80VDC | ||||||
Cooling method | Auto detective cooling fan | ||||||||
LCD | AC input/output voltage, battery capacity percentage, load capacity percentage, solar input voltage, solar charge current, solar charge voltage etc... | ||||||||
Communication port | RS232(optional) | ||||||||
Working mode | Battery priority(auto) | Additional manual switch |
Supply Ability
--