SAKO 10kva 20kva 30kva 40kva 50kva solar system 10kw 3 phase 10000 watt hybrid solar inverter
- Minimal order
- 100 pieces
Message Phone call
Product Specifications
--
Product Description
Overview
Quick Details
Warranty: Other
Free installation service: No
Place of Origin: Guangdong, China
Brand Name: SAKO
Model Number: SUNMAX-1KW
Application: Home
Load Power (W): 50kw, 30KW, 20KW, 10KW
Work Time (h): 24h
Pre-sales project design: Y
Specification: Normal
Input Voltage (VDC): 12/24VDC
Input AC Range (VAC): 90Vac±4%-135Vac±4% or 184Vac±4%-253Vac±4%
AC Efficiency: > 95%
Output Current:: 25A
Max PV input voltage( Vdc): ≤150Vdc
The rated charge current (A): 30A MPPT
Certification: CE,ISO9001,ISO14000,ISO1800
Size: 617*312*385mm
Output Voltage (V): 110V/220V/230V/240V
Supply Ability
Supply Ability: 10000 Piece/Pieces per Month The order is subject to the actual price.
Packaging & Delivery
SAKO SUNMAX 1KW/12V/24V Off Grid Hybrid Pure Sine Wave Solar Inverter With MPPT Charge Controller /Solar Power System
Main Features:
1. Big LCD display
2. Over load protection
3. Short circuit protection
4. Over temperature protection
5. Microprocessor Control Guarantees High Reliability
6. With Intelligent Big AC Charger
7. 5Step Progressive Charging
8. User Select 5 Types Battery
9. User Setting Battery Charge Current
10.Automatically And Swiftly Line To Battery Switchover
11.High Efficiency Using Line-interactive Circuit Technology
12.Easy To Install&Easy To Use
13.MPPT Solar charge controller built inside
14.High-powert,Multi-Stage Battery Charge
Product Show




| MODEL | SUNMAX 1KW | SUNMAX 2KW | SUNMAX 3KW | SUNMAX 4KW | SUNMAX 5KW | SUNMAX 6KW | ||||||
| SPECIFICATION | ||||||||||||
| DC INPUT | ||||||||||||
| Input Voltage(Vdc) | 12V/24V | 24V/48V | ||||||||||
| Min DC start voltage(Vdc) | 10V/20V | 20V/40V | ||||||||||
| AC Bypass | ||||||||||||
| Nominal Input Voltage | 110V or 230Vac (Waveform: Sine wave or as generator) | 230Vac(Waveform: Sine wave or as generator) | ||||||||||
| Input AC Range(Vac) | 90Vac±4%-135Vac±4% or 184Vac±4%-253Vac±4% | 184Vac±4%-253Vac±4% | ||||||||||
| Frequency Range(HZ) | 57Hz or 60Hz (47Hz-53Hz for 50Hz, 57Hz-63Hz for 60Hz) | |||||||||||
| Input Frequency(Hz) | 50Hz/60Hz (Auto detection) | |||||||||||
| Bypass Output Voltage(Vac) | Same as input voltage | |||||||||||
| Bypass Output Frequency(Hz) | Same as input frequency | |||||||||||
| Max Bypass Overload Current | 10A | 30A | 40A | |||||||||
| AC Efficiency | > 95% | |||||||||||
| Transfer Time(ms) | 20ms (typical) | |||||||||||
| MPPT CHARGE CONTROLLER BUILT INSIDE | ||||||||||||
| The rated charge current (A) | 40A | 40A | 50A | 50A | 60A | 60A | ||||||
| Max PV input voltage( Vdc) | ≤150Vdc | |||||||||||
| The battery voltage (Vdc) | 12V/24V/48V Auto identify and adaptive | |||||||||||
| Battery types for selection | Lead Acid/Gel/Flood battery/Activated the sleeping of damaged batteries | |||||||||||
| Fast charge voltage( vdc) | 14.0V for 12V system/28V for 24V system/56V for for 48V system | |||||||||||
| Float Charge Voltage(Vdc) | 13.8V for 12V system/27.6V for 24V system/55.2V for 48V system | |||||||||||
| Over charge Protection Vol.(Vdc) | 15V for 12V system/30V for 24V system/60V for 48V system | |||||||||||
| Over charge Recovery Vol.(Vdc) | 13.6V for 12V system/27.2V for 24V system/54.4V for 48V system | |||||||||||
| CHARGER | ||||||||||||
| Charge mode Input Voltage Range | 80~145Vac or 95~255Vac | 100~255Vac | ||||||||||
| Automatic Charge mode | Three stage charge mode:Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | |||||||||||
| Nominal Charge Voltage | According to the battery type setup | |||||||||||
| Charge Current(A) | 17.5A/35A/70A | |||||||||||
| Charge boost voltage(v) | According to the battery type setup( 12V BAT:14-15.5v 24V BAT: 28-31V 48V BAT:56-62V ) | |||||||||||
| Charge Floating Voltage(V) | According to the battery type setup (12V BAT: 13.3-13.7, 24v BAT: 26.6-27.6, 48V BAT:53.2-55.2V ) | |||||||||||
| Over Charge Protection | Bat. V ≥15.7Vdc, beeps 0.5s every 1s & fault after 60s (15.7 for 12v, 31.4V for 24V, 62.8V for 48V ) | |||||||||||
| Charger Short Circuit Protection | Circuit breaker | |||||||||||
| (INVERTER) | ||||||||||||
| Capacity(VA) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | ||||||
| Output Power(W) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | ||||||
| Power Factor(PF) | 1 | |||||||||||
| Output Voltage | 120V or 230Vac (Sine wave ) | 230Vac (Sine wave ) | ||||||||||
| Output Frequency | 50/60 ± 0.3Hz(auto tracking main first power connection) | |||||||||||
| Wave | pure sine wave | |||||||||||
| Inversion Efficiency | >88% | |||||||||||
| Over load capacity | (110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes; (125%<load<150%) ±10%: Fault (shutdown output) after 60s; Load>150% ±10%: Fault (shutdown output) after 20s |
|||||||||||
| Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery, 21.0Vdc ± 0.6Vdc for 24V battery, 42.0Vdc ± 1.2Vdc for 48V battery | |||||||||||
| Power saver | Load 25W | |||||||||||
| AMBIENT | ||||||||||||
| Noise(dB) | 60dB max. | |||||||||||
| Temperature | 0°C to 40°C | |||||||||||
| Humidity | 5% to 95% | |||||||||||
| Sea Level(m) | ≤1500 | |||||||||||
| DIMENSION | ||||||||||||
| Product size L×W×H(mm) | L488mm*W219mm*H304mm | L608mm*W219mm*H304mm | ||||||||||
| Packing size | L617mm*W312mm*H385mm | L760mm*W312mm*H385mm | ||||||||||
| Weight(Kg) | 23/24.5 | 24.5/26 | 30.5/31.5 | 38.8/40.8 | 43.5/45.5 | 50.5/52.5 | ||||||


new products


other Products


Company Information







Certifications

Packaging & Shipping

FAQ
Q1: How to choose a right inverter?
A1:Tell us your demand, then our sales will recommend a suitable inverter to you.
Q2: What's the different between inverter and solar inverter?
A2: Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.
Q3: How about the delivery time?
A3: 7 days for sample; 25 days for bulk order.
Q4: What is the warranty of inverter?
A4: One year warranty on SAKO-Solar product.
Q5: How to solve the technical problem?
A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.