Solar System Working Station (controller system)
- Minimal order
- 100 pieces
Message Phone call
Product Specifications
Type
Controller
Product Description
WORK STATION for separated pressurized solar water heater system
CONTROLLER SYSTEM
Performance of Swimming Pool Heat Exchanger:
Model | Normal Capacity | Pool Capacity | ||
kW | kBtu/Hr | Gallons@1°F/hr | M3@1°C/hr | |
SP-55 | 16 | 55 | 4700 | 32 |
SP-85 | 25 | 85 | 7300 | 49.7 |
SP-155 | 45 | 155 | 13300 | 90.6 |
SP-210 | 60 | 210 | 18000 | 122.6 |
SP-300 | 88 | 300 | 25800 | 175.8 |
SP-360 | 105 | 360 | 31500 | 214.6 |
SP-600 | 175 | 600 | 52500 | 357.7 |
SP-1200 | 352 | 1200 | 105600 | 719 |
SP-2400 | 704 | 2400 | 211200 | 1438 |
SP-3000 | 880 | 3000 | 264000 | 1797.5 |
SP-3600 | 1056 | 3600 | 316800 | 2157 |
SP-4500 | 1310 | 4500 | 396000 | 2700 |
SP-5000 | 1460 | 5000 | 439000 | 3000 |
Introduce
APPLICATIONS CAPACITY Max.number of collectors:1 Max.number of storage tanks:1 Max.number of relays:4 Max.number of sensors:4 Max.number of application system:1
Main technical data
TECHNICAL DATA
Dmension: 120mm x120mm x18mm
Power supply:200V-240V AC or 100V-130V AC,50-60Hz. .
Power consumption: < 3W
Accuracy of temperature measuring: ± 2oC
Range of collector temperature measuring: -10oC ~200oC
Range of tank temperature measuring: 0oC ~110oC
Suitable power of pump: 3 pumps possible to be connected, power of each pump < 200W .
Suitable power of electrical heater: 1pc = 1500W .
Inputs: 4 sensors,
1pcs*Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),
3pcs*NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),
Outputs:4 relays, for circulation pumps or 3-way electromagnetic valve
Ambient temperature:-10oC ~ 50oC.
Water proof grade: IP40.
Main functions
MAIN FUNCTIONS
Timing heating
Temperature difference control 1*ΔT
Collector emergency shutdown
Collector cooling function
Collector low temperature protection
Collector frost protection
Tank re-cooling function
Celsius and Fahrenheit temperature switch
Maximum temperature of tank ( 1*storage tank)
Anti-Legionella function
Temperature controlled hot water circulation pump
High temperature by-pass function(Collector cooling down)
Manual Control( for 4 outputs:P1,P2,R1,H1)
Password setting
Recovery to factory setting
Holiday fucntion
Manual Heating
Temperature query function
Memory Protection
Screen protection
Trouble shooting
Trouble protection
Trouble checking
Memory Protection
Anti-dry heating Protection
Screen protection
Supply Ability
--
Packaging and Shipping
Lead time
--
Port
--
Packaging details
--