Model | Solis-1P2.5K-4G | Solis-1P3K-4G | Solis-1P3.6K-4G | Solis-1P4K-4G |
Input DC | ||||
Max. DC input power(kW): | 3 | 3.5 | 4.2 | 4.6 |
Max. DC input voltage(V): | 550 | 600 | 600 | 600 |
Start-up voltage(V): | 60 | 120 | 120 | 120 |
MPPT voltage range(V): | 50-450 | 90-520 | 90-520 | 90-520 |
Max. input current(A/B): | 11A+11A | 11A+11A | 11A+11A | 11A+11A |
MPPT number: | 2 | 2 | 2 | 2 |
Max input strings number: | A:1; B:1 | A:1; B:1 | A:1; B:1 | A:1; B:1 |
Max. Short Circuit current for each MPPT: | 17.2A+17.2A | 17.2A+17.2A | 17.2A+17.2A | 17.2A+17.2A |
Output AC | ||||
Rated output power(kW): | 2.5 | 3 | 3.6 | 4 |
Max. apparent output power(kVA): | 2.8 | 3.3 | 4 | 4.4 |
Max. output power(kW): | 2.8 | 3.3 | 4 | 4.4 |
Rated grid voltage(V): | 220/230 | 220/230 | 220/230 | 220/230 |
Rated grid frequency(Hz): | 50/60 | 50/60 | 50/60 | 50/60 |
Grid frequency range(Hz): | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 |
Operation phase: | Single | Single | Single | Single |
Rated grid output current(A): | 11.4/10.9 | 13.6/13 | 16/15.7 | 16/15.7 |
Max. output current(A): | 13.3 | 15.7 | 16 | 21 |
THDi (at rated output power): | <3% | <3% | <3% | <3% |
DC injection current(mA): | <0.5%In | <0.5%In | <0.5%In | <0.5%In |
Power Factor (at rated output power): | 0.8leading ... 0.8lagging | |||
Efficiency | ||||
Max.efficiency: | 97.8% | 97.8% | 97.8% | 98.1% |
EU efficiency: | 97.1% | 97.1% | 97.1% | 97.3% |
MPPT efficiency: | >99.5% | >99.5% | >99.5% | >99.5% |
Protection | ||||
DC reverse-polarity protection: | Yes | Yes | Yes | Yes |
Short circuit protection: | Yes | Yes | Yes | Yes |
Output over current protection: | Yes | Yes | Yes | Yes |
Output over voltage protection: | Yes | Yes | Yes | Yes |
Insulation resistance monitoring: | Yes | Yes | Yes | Yes |
Residual current detection: | Yes | Yes | Yes | Yes |
Surge protection: | Yes | Yes | Yes | Yes |
Islanding protection: | Yes | Yes | Yes | Yes |
Temperature protection: | Yes | Yes | Yes | Yes |
Integrated DC switch: | Optional | Optional | Optional | Optional |
General Data | ||||
Dimensions(mm): | 310W*543H*160D (mm) | |||
Weight(kg): | 11.5 | |||
Topology: | Transformerless | |||
Self consumption (night): | <1W(Night) | |||
Ingress protection: | Ip65 | |||
Noise emission(typical): | <20 dBA | |||
Cooling concept: | Natural convection | |||
Max.operation altitude:: | 4000m | |||
Designed lifetime: | >20years | |||
Relative humidity: | 0~100% | |||
Operating ambient temperature range: | -25~60ºC | |||
Grid connection standard: | EN50438, G98, G99, AS4777.2:2015, VDE0126-1-1, IEC61727, VDE N4105 | |||
Safty/EMC standard: | IEC62109-1/-2, NB/T 32004, EN61000-6-1, EN61000-6-3 | IEC62109-1/-2 ,NB/T 32004 | IEC62109-1/-2, NB/T 32004, EN61000-6-1, EN61000-6-3 | |
Features | ||||
DC connection: | MC4 | |||
AC connection: | IP67rated plug | |||
Display: | LCD,2*20 Z. | |||
Communication connections: | 4 pins RS485 connector | |||
Monitoring: | WiFi or GPRS | |||
Warranty: | 5/10/15/20 Years | |||
Technical specifications
Model | Solis-1P4.6K-4G | Solis-1P5K-4G | Solis-1P6K-4G |
Input DC | |||
Max. DC input power(kW): | 5.3 | 5.8 | 6.6 |
Max. DC input voltage(V) : | 600 | 600 | 600 |
Start-up voltage(V) : | 120 | 120 | 120 |
MPPT voltage range(V) : | 90-520 | 90-520 | 90-520 |
Max. input current(A/B) : | 11A+11A | 11A+11A | 11A+11A |
MPPT number : | 2 | 2 | 2 |
Max input strings number : | A:1; B:1 | A:1; B:1 | A:1; B:1 |
Max. Short Circuit current for each MPPT : | 17.2A+17.2A | 17.2A+17.2A | 17.2A+17.2A |
Output AC | |||
Rated output power(kW): | 4.6 | 5 | 6 |
Max. apparent output power(kVA) : | 5 | 5 | 6 |
Max. output power(kW) : | 5 | 5 | 6 |
Rated grid voltage(V) : | 220/230 | 220/230 | 220/230 |
Rated grid frequency(Hz) : | 50/60 | 50/60 | 50/60 |
Grid frequency range(Hz) : | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 |
Operation phase : | Single | Single | Single |
Rated grid output current(A) : | 20.9/20 | 22.7/21.7 | 27.3 |
Max. output current(A) : | 23.8(21.7 for AUS) | 25(21.7for AUS) | 27.3 |
THDi (at rated output power) : | <3% | <3% | <3% |
DC injection current(mA) : | <0.5%In | <0.5%In | <0.5%In |
Power Factor (at rated output power) : | 0.8leading ... 0.8lagging | ||
Efficiency | |||
Max.efficiency: | 98.1% | 98.1% | 98.1% |
EU efficiency: | 97.3% | 97.3% | 97.3% |
MPPT efficiency : | >99.5% | >99.5% | >99.5% |
Protection | |||
DC reverse-polarity protection: | Yes | Yes | Yes |
Short circuit protection : | Yes | Yes | Yes |
Output over current protection : | Yes | Yes | Yes |
Output over voltage protection : | Yes | Yes | Yes |
Insulation resistance monitoring : | Yes | Yes | Yes |
Residual current detection : | Yes | Yes | Yes |
Surge protection : | Yes | Yes | Yes |
Islanding protection : | Yes | Yes | Yes |
Temperature protection : | Yes | Yes | Yes |
Integrated DC switch : | Optional | Yes | Yes |
General Data | |||
Dimensions(mm): | 310W*543H*160D (mm) | ||
Weight(kg) : | 11.5 | ||
Topology : | Transformerless | ||
Self consumption (night) : | <1W(Night) | ||
Ingress protection : | Ip65 | ||
Noise emission{typical} : | <20 dBA | ||
Cooling concept : | Natural convection | ||
Max.operation altitude : | 4000m | ||
Designed lifetime : | >20years | ||
Relative humidity : | 0~100% | ||
Operating ambient temperature range : | -25~60ºC | ||
Grid connection standard : | EN50438, AS4777.2:2015, VDE0126-1-1, IEC61727, VDE N4105, G98, G99 | ||
Safty/EMC standard: | IEC62109-1/-2, NB/T 32004, EN61000-6-1, EN61000-6-3 | IEC62109-1/-2, NB/T 32004 | |
Features | |||
DC connection: | MC4 | ||
AC connection : | Ip67 rated plug | ||
Display : | LCD,2×20 Z. | ||
Communication connections : | 4 pins RS485 connector | ||
Monitoring : | WiFi or GPRS | ||
Warranty : | 5/10/15/20 Years | ||
Technical specifications
Model | Solis-1P7K-4G | Solis-1P8K-4G | Solis-1P9K-4G | Solis-1P10K-4G |
Input DC | ||||
Max. DC input power(kW): | 8 | 9.2 | 10.8 | 11.5 |
Max. DC input voltage(V): | 600 | 600 | 600 | 600 |
Start-up voltage(V): | 120 | 120 | 120 | 120 |
MPPT voltage range(V): | 100-500 | 100-500 | 100-500 | 100-500 |
Max. input current(A/B/C): | 10A+10A+10A | 10A+10A+10A | 10A+10A+10A | 10A+10A+10A |
MPPT number: | 3 | 3 | 3 | 3 |
Max input strings number: | A:1; B:1; C:1 | A:1; B:1; C:1 | A:1; B:1; C:1 | A:1; B:1; C:1 |
Max. Short Circuit current for each MPPT: | 15.6A+15.6A+15.6A | 15.6A+15.6A+15.6A | 15.6A+15.6A+15.6A | 15.6A+15.6A+15.6A |
Output AC | ||||
Rated output power(kW): | 7 | 8 | 9 | 10 |
Max. apparent output power(kVA): | 7.7 | 8.8 | 9.9 | 10 |
Max. output power(kW): | 7.7 | 8.8 | 9.9 | 10 |
Rated grid voltage(V): | 220/230 | 220/230 | 220/230 | 220/230 |
Rated grid frequency(Hz): | 50/60 | 50/60 | 50/60 | 50/60 |
Grid frequency range(Hz): | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 |
Operation phase: | Single | Single | Single | Single |
Rated grid output current(A): | 31.8/30.4 | 36.4/34.8 | 40.9/39.1 | 45.5/43.5 |
Max. output current(A): | 33.7 | 36.6 | 41.3 | 45.9 |
THDi (at rated output power): | <3% | <3% | <3% | <3% |
DC injection current(mA): | <0.5%In | <0.5%In | <0.5%In | <0.5%In |
Power Factor (at rated output power): | 0.8leading ... 0.8lagging | |||
Efficiency | ||||
Max.efficiency: | 98.1% | 98.1% | 98.1% | 98.1% |
EU efficiency: | 97.6% | 97.6% | 97.6% | 97.6% |
MPPT efficiency: | >99.5% | >99.5% | >99.5% | >99.5% |
Protection | ||||
DC reverse-polarity protection: | Yes | Yes | Yes | Yes |
Short circuit protection: | Yes | Yes | Yes | Yes |
Output over current protection: | Yes | Yes | Yes | Yes |
Output over voltage protection: | Yes | Yes | Yes | Yes |
Insulation resistance monitoring: | Yes | Yes | Yes | Yes |
Residual current detection: | Yes | Yes | Yes | Yes |
Surge protection: | Yes | Yes | Yes | Yes |
Islanding protection: | Yes | Yes | Yes | Yes |
Temperature protection: | Yes | Yes | Yes | Yes |
Integrated DC switch: | Optional | Optional | Optional | Optional |
General Data | ||||
Dimensions(mm): | 333W*573H*249D (mm) | |||
Weight(kg): | 18 | |||
Topology: | Transformerless | |||
Self consumption (night): | <1W(Night) | |||
Ingress protection: | Ip65 | |||
Noise emission(typical): | <30 dBA | |||
Cooling concept: | Natural convection | |||
Max.operation altitude:: | 4000m | |||
Designed lifetime: | >20years | |||
Relative humidity: | 0~100% | |||
Operating ambient temperature range: | -25~60ºC | |||
Grid connection standard: | EN50438, G98, G99, AS4777.2:2015, VDE0126-1-1, IEC61727, VDE N4105 | |||
Safty/EMC standard: | IEC62109-1/-2, NB/T 32004, EN61000-6-1, EN61000-6-3 | |||
Features | ||||
DC connection: | MC4 | |||
AC connection: | IP67rated plug | |||
Display: | LCD,2*20 Z. | |||
Communication connections: | 4 pins RS485 connector | |||
Monitoring: | WiFi or GPRS | |||
Warranty: | 5/10/15/20 Years | |||