Wind solar hybrid charge controller 1KW/2KW/3KW
- Minimal order
- 100 pieces
Message Phone call
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin: Shandong, China
Brand Name: deming
Model Number: FKJ-A2
Application: Wind Controller
Rated Voltage: 24V
Supply Ability
Supply Ability: 10000 Piece/Pieces per Week
Packaging & Delivery


FKJ–A model Product Characteristics
1. The product can be manufactured in accordance with either JB/T6939.1-2004 industrial standard, GB/T 19115.1-2003 national standard or users’ technical requirements.
2. FKJ-A1 and FKJ-A2 controllers adopt multiple-line three-phase load discharging control.
3. The total power of three-phase load discharging is 220% larger than the rated power of the wind turbine generator. The three-phase load discharging power of the first line is 80-100% of the rated power of the wind turbine generator; in case of exceeding the scope of the first line load discharging power, the three-phase load discharging of the second line will automatically start to ensure safe operation of the overall wind turbine generation system.
4. Under the circumstances of decoupling and damage of the battery, the three-phase load discharging will automatically start to avoid the idle run of the wind turbine generator and the occurrence of runaway accident.
5. It has reverse connection, anti-decoupling and damage-resisting protection of the battery.
6. Over-charging protection of the battery: When the battery is full (the battery pressure reaching 125% of the rated pressure), the controller will automatically carry out three-phase load discharging to stop charging the battery.
7. Auto recovery of battery charging: When the battery pressure reduces to 108% of the rated pressure, the load discharger will stop three-phase load discharging to automatically recover battery charging.
8. According to the category of the wind turbine generator, the controller can be additionally equipped with mechanical yawing, swing-tai, mechanical or hydraulic, pneumatic, magnetic and other brake functions.
9. LED status indication: Clearly present the working status of the wind turbine generator, solar panel, battery and controller.
10. Ammeter and voltmeter indication: Indicate the charging current and voltage of the battery.
11. The controller is equipped with manual three-phase load discharging switch; the user may use it according to actual circumstances. When using this switch, the wind turbine generator will forcibly carry out three-phase load discharging.




Technical Parameters of the FKJ-A2 Off - Grid Wind Solar Hybrid Controller
Type | 1KW24Vdc | 1KW48Vdc | 2KW48V | 2KW96Vdc | 3KW48Vdc | |
Wind turbine rated power | 1KW | 1KW | 2KW | 2KW | 1KW | |
Wind turbine max. power | 2KW | 2KW | 4KW | 4KW | 2KW | |
Solar panel power | 300Wp | 300Wp | 600Wp | 600Wp | 300Wp | |
Battery | 24Vdc | 48Vdc | 48Vdc | 96Vdc | 48Vdc | |
Function | Rectifier,charge, control | |||||
Display mode | LCD | |||||
Display content | Wind turbine voltage, wind turbine current, wind turbine power, solar panel voltage, solar panel current, solar panel power, battery voltage, charge current | |||||
Wind turbine 3-phase dump load voltage | 29±1Vdc | 58±1Vdc | 58±1Vdc | 116±1Vdc | 58±1Vdc | |
Wind turbine 3-phase brake voltage | 30±1Vdc | 60±1Vdc | 60±1Vdc | 120±1Vdc | 60±1Vdc | |
Wind turbine Recovery charging voltage | 27±1Vdc | 54±1Vdc | 54±1Vdc | 108±1Vdc | 54±1Vdc | |
Solar controller stop charging voltage | 30±1Vdc | 60±1Vdc | 60±1Vdc | 120±1Vdc | 60±1Vdc | |
Solar restore charge voltage | 27±1Vdc | 54±1Vdc | 54±1Vdc | 108±1Vdc | 54±1Vdc | |
Low-voltage of the battery | 20±1Vdc | 40±1Vdc | 40±1Vdc | 80±1Vdc | 40±1Vdc | |
Self-provided connecting wire of the battery | >10mm² | >4mm² | >10mm² | >6mm² | >12mm² | |
Work environment temperature | -30-60°C | |||||
Relative humidity | <90% No condensation | |||||
Noise(1m) | <40dB | |||||
Degree of protection | IP20(Indoor) | |||||
Cooling method | Forced air cooling | |||||
*Communication interface (optional) | RS485/USB/GPRS/Ethernet | |||||
*Temperature compensation (optional) | -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C | |||||
Size of the controller (mm) | 440*350*255 | |||||
Weight of the controller | 9KG | |||||
Size of the dump load (mm) | 350*330*205 | 480*360*200 | ||||
Weight of the dump load | 5.5Kg | 6.5Kg | ||||
*Above parameter only for reference, could be custom made to user specifications.


Payment

Company Information



More products






Supply Ability
--
Packaging and Shipping
Lead time
--
Port
--
Packaging details
--








