Product Specifications

--

Product Description

Functional details

1.    Hot plug

Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.

2.    Advanced current sharing technology

Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than ±0.5A.

3.    Control of input limited power

Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 320 Vac ~ 530 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.

4.   Control of output constant power

When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.

Note:

The module uses two operating modes with output voltage ranges of 50V to 600V and 50 to 750V.  Boot without a demand     voltage.The default operation is in the low-voltage segment mode; if the monitored demand voltage is higher than 600V, the module will automatically switch to the high-voltage segment mode. When the demand voltage is lower than 550V At the same time, it automatically cuts back to the low pressure section mode.

The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.

5.    Temperature limited power

Under 55°C ambient temperature, the module can output full power of 20kW;

Over 55°C ambient temperature, the module shall be used by derating with the power Linearly .

Under 65°C ambient temperature, the allowable output power of the module is 10kW.

Under 75°C ambient temperature, the output power of the module is reduced to 0.

6.    Regulation of output current limiting point

The module has the function of stepless current limiting. The current limiting point within the scope of 0~33.3A(High voltage)/0A~50A(low voltage) is adjustable through the external monitoring module. When the output voltage is within 50Vdc ~ 750Vdc, the current limiting accuracy of the module is ±0.3A.

7.    Regulation of output voltage

The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.

8.    Fan control

The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.

9.    Protection of input overvoltage/ voltage shortage

When the input voltage is less than 260 Vac or more than 530 Vac, the protection indicator light is on and the module stops working, without output.

when the module is in Single-phase communication mode, the input voltage is less than 160 Vac or more than 300 Vac, the protection indicator light is on and the module stops working, without output Meanwhile, this condition will be transmitted to the monitoring module. The function can be recovered automatically.

10.  Output overvoltage protection

The overvoltage protection point is 260Vdc ~770Vdc (±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.

11.  Over-temperature protection

The environmental over-temperature protection point is 80°C. When the DC panel has a temperature over 100°C, the module will stop working; when the DC panel has a temperature below 90°C, the module will automatically work again.

12.  Protection of internal bus fault

When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.

13.  Short circuit protection

In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".

14.  Interruption of background communication

After module communication interruption, the protection indicator light will flash and the module will be subject to shutdown protection. When the communication is recovered, the protection indicator light recovers to normal state and the module works again.

15.  Protection against fan fault

In case of module communication interruption over 8S, the module will be subject to shutdown protection, without voltage output and the protection indicator light will flash. After fault removal, the module will work automatically again.

16.  Monitoring performance

The charging module is equipped with CAN bus. It can also be converted to RS232 via the protocol converter, and the RS485 protocol communicates with the external monitoring module.Refer to Table 1-2 for the list of the monitoring information.

Command / Signal Issued by the Monitoring Module of the Charger SystemCharging Module Information Collected by the Monitoring Module of the Charger System
Module start-up/ shutdown
Setting of function of output current slow rise
Regulation of the current limiting point of charging module
 Regulation of the output voltage of charging module
 
Input voltage, output voltage and output current
Current limiting point and temperature of charging module
DC output overvoltage point
DC switch state
Fault alarm and protection alarm
Temperature limited power and input limited power
AC power failure
Current unbalance

Technical Parameters

Table 1-3   Technical Parameters of Charging Module

CategoryNameParameter
Environmental conditionsOperation temperature-40°C ~ +75°C, derating is require when the temperature is above 55°C.
Storage temperature-40°C ~ +70°C
Relative humidity≤95%RH, without condensation
Cooling modeForced air cooling
Altitude2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l.
Atmospheric pressure79 kPa ~ 106 kPa
AC inputInput systemThree phases + PE
Voltage range260 Vac ~ 530 Vac
The maximum static voltage borne under no operation600 Vac
Rated voltage400 Vac
Maximum current32A
Grid frequency45 Hz~ 65 Hz
Rated frequency50Hz/60Hz
DC outputVoltage range50 Vdc ~ 750Vdc
Current range0 ~ 33.3A (high voltage)/ 0~50A(low voltage)
Rated current26A@750V (required for setting of current limiting point,750V is 26.67A)
Steady voltage precision<±0.5%
Steady current precision≤±1% (rated range of 20% ~ 100% for output load)
Load regulation rate≤±0.5%
Grid regulation rate≤±0.1% (testing range is 320V ~ 530V)
Startup overshoot≤±3%
Peak-to-peak value noise≤1% (150~750V, 0~20MHz)
Power factor and THDPower factor≥0.95   Full-load output power of @20%~50%
≥0.98   Full-load output power of @50%~100%
≥0.99  Full-load output power, input nominal voltage and frequency of @100%
THD≤5%  Full-load output power of  @50%~100%
EfficiencyUnder Rated input voltage95.2%,@750V,50%~100%
EMCEmissionClassA , Meet the requiremnt of  NB/T 33001-1-2010,NB/T 33008-1-2013  
ImmunityC lassA , Meet the requiremnt of  NB/T 33001-1-2010,NB/T 33008-1-2013  
OtherInstant impulse current upon startup<45A
Current sharingIn case of load of 10%~100%, the module current sharing error ≤ rated output current of ±5%.
Noise65dB(1m away,
Startup duration (select the startup mode through the monitoring module)Normal startup mode: the time delay from AC power-on to module output is ≤ 8s.
Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s.
Earthing resistanceEarthing resistance ≤ 0.1Ω, bearable current ≥ 25A
Surge protectionMeets IEEE C62 41-1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave)
Insulation  resistanceThe insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ.
Insulation strengthAC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA;
AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady-state leakage current is less than
1mA;
DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA;
 ROHSR5
Mechanical parametersSize84Mm (H) ×226mm (W) ×395mm (D)
Weight≤11kg

Packaging & Shipping

Why Whoose our product

Contact information

 

Supply Ability

--

Packaging and Shipping

Lead time

--

Port

--

Packaging details

--


Comments
Welcome to zddshop comments! Please keep conversations courteous and on-topic. To fosterproductive and respectful conversations, you may see comments from our Community Managers.
Sign up to post
Sort by
Show More Comments

Other offers of this wholesaler

Copyright 2023-2025 - www.zddshop.com All Rights Reserved