Product Specifications
Type
on-Line
Product Description
The series DC-AC power inverter can be fitted with solar system
With high conversion efficiency.
DC-AC power inverter
Adopt Special Microprocessor Chip Control
Advanced Intelligent IGBT Module (IPM)
High reliability and strong anti-impact ability
LCD Display, with the simply operation
RS232/485 communication interface, it is applicable to local
And remote monitoring
Easy installation
Adopts Static bypass and switch to be uninterruptible
Over/low voltage, short circuit, overload etc functions
Rated Capacity(VA) | SL-600VA | SL-1KVA | SL-1.5KVA | SL-2KVA | SL-3KVA | SL-4KVA | SL-5KVA | SL-6KVA | ||
Output voltage(W) | Rated Capacity*0.8 | |||||||||
Work mode | Low frequency online interactive | |||||||||
Phase | Single phase( L+N+G ) | |||||||||
Rated Input voltage | 100/110/115/127V, 220/230/240V ( According to the user's power standard ) | |||||||||
Input voltage range | ±25% | |||||||||
Input nominal frequency | 50/60Hz ( adaptive adjustment ) | |||||||||
Input frequency range | ±5% | |||||||||
Voltage stabilizing function | Adopt Relay smart multi-gear adjusting voltage | |||||||||
Voltage stabilizing output precision | ±5% | |||||||||
Rated Battery Voltage | 12V/24V/48V/96V/110V/220V (12V only used for 650VA, 24V only used for 1000VA~1500VA, 48V only used for 2000VA~6000VA ) | |||||||||
Charge mode | three-stage intelligent battery charging | |||||||||
Float charging voltage | 13.5V/27V/54V/108V/121.5V/243V | |||||||||
Equalized charging voltage (optional) | 14.1V/28.2V/56.4V/112.8V/126.9V/253.8V | |||||||||
Temp. Compensation voltage | 3mV/(cell battery) | |||||||||
Charge power | Rated capacity*20% | |||||||||
Output phase | Single phase(L+N+G) | |||||||||
Nominal voltage | Equal to input rated voltage | |||||||||
Inverter output voltage | 100/110/115/127V;220/230/240V ( According to the user's power standard ) | |||||||||
Inverter voltage stability | ±1%(steady load ), ±3% (fluctuation of load ) | |||||||||
Inverter frequency stability | 50Hz, 60Hz<±0. 5% | |||||||||
Crest factor | >3:1 | |||||||||
Inverter output waveform distortion degree | Pure sine wave, Linear load<3%; non-linear load<5% | |||||||||
Transfer time | <5ms | |||||||||
Overload protection | Overload level | utility power mode | Battery mode | |||||||
105%~125% | >10mins | >1mins | ||||||||
125%~150% | >1mins | Immediate protection | ||||||||
>150% | Immediate protection |
|
||||||||
Input protection | Voltage, frequency ultralimit protection | |||||||||
Output protection | Overcurrent, short circuit protection | |||||||||
Battery protection | Overcharge, overdischarge protection | |||||||||
Temperature protection | Over- temperature protection | |||||||||
Hardware fault protection | Fuse over current protection, surge voltage protection | |||||||||
Alarm function | Audio alarm | |||||||||
Work Environment | Temperature: 0~40, Relative humidity: 30%~90% , Altitude<2000m ( power reduce 1% every 100M raised, 4000M utmost) | |||||||||
Cooling method | Forced ventilation | |||||||||
Communication interface | RS232(optional usb, snmp card ) | |||||||||
Protection level | IP30 | |||||||||
Safety performance | I/O on ground resistance (3000VAC), stray current less than 3.5mA, insulation resistance exceeding 2MΩ(500VDC) | |||||||||
dimension (W*H*D) mm | 482×88×300 | 482×133×400 | 482×222×450 |
Supply Ability
--
Packaging and Shipping
Lead time
--
Port
--
Packaging details
--
Comments
Welcome to zddshop comments! Please keep conversations courteous and on-topic. To fosterproductive and respectful conversations,
you may see comments from our Community Managers.
Sign up to post
Show More Comments