Product Specifications
--
Product Description
Product Description
Technical specifications
Model | Solis-25K-5G | Solis-30K-5G | Solis-33K-5G | Solis-36K-5G |
Input DC | ||||
Max. DC input power(kW): | 33 | 39 | 43 | 47 |
Max. DC input voltage(V): | 1100 | 1100 | 1100 | 1100 |
Start-up voltage(V): | 180 | 180 | 180 | 180 |
MPPT voltage range(V): | 200-1000 | 200-1000 | 200-1000 | 200-1000 |
Max. input current(A): | 26+26+26 | 26+26+26 | 26+26+26 | 26+26+26+26 |
MPPT number: | 3 | 3 | 3 | 4 |
Max input strings number: | A:2; B:2; C:2 | A:2; B:2; C:2 | A:2; B:2; C:2 | A:2; B:2; C:2; D:2 |
Max. Short Circuit current for each MPPT: | 39+39+39 | 39+39+39 | 39+39+39 | 39+39+39+39 |
Output AC | ||||
Rated output power(kW): | 25 | 30 | 33 | 36 |
Max. apparent output power(kVA): | 27.5 | 33 | 36.3 | 39.6 |
Max. output power(kW): | 27.5 | 33 | 36.3 | 39.6 |
Rated grid voltage(V): | 400 | 400 | 400 | 400 |
Rated grid frequency(Hz): | 50/60 | 50/60 | 50/60 | 50/60 |
Grid frequency range(Hz): | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 |
Operation phase: | 3/N/PE | 3/N/PE | 3/N/PE | 3/N/PE |
Rated grid output current(A): | 36 | 43.3 | 47.6 | 51.9 |
Max. output current(A): | 41.8 | 50.2 | 55.1 | 60.2 |
THDi (at rated output power): | <3% | <3% | <3% | <3% |
DC injection current(mA): | <0.5%In | <0.5%In | <0.5%In | <0.5%In |
Power Factor (at rated output power): | 0.8leading ... 0.8lagging | |||
Efficiency | ||||
Max.efficiency: | 98.8% | 98.8% | 98.8% | 98.8% |
EU efficiency: | 98.3% | 98.3% | 98.3% | 98.3% |
MPPT efficiency: | >99.5% | >99.5% | >99.5% | >99.5% |
Protection | ||||
DC reverse-polarity protection: | Yes | Yes | Yes | Yes |
Short circuit protection: | Yes | Yes | Yes | Yes |
Output over current protection: | Yes | Yes | Yes | Yes |
Output over voltage protection: | Yes | Yes | Yes | Yes |
Insulation resistance monitoring: | Yes | Yes | Yes | Yes |
Residual current detection: | Yes | Yes | Yes | Yes |
Surge protection: | DC Type II/ AC Type II | DC Type II/ AC Type II | DC Type II/ AC Type II | DC Type II/ AC Type II |
Islanding protection: | Yes | Yes | Yes | Yes |
Temperature protection: | Yes | Yes | Yes | Yes |
Integrated DC switch: | Optional | Optional | Optional | Optional |
Strings monitoring: | Yes | Yes | Yes | Yes |
Anti-PID: | Optional | Optional | Optional | Optional |
General Data | ||||
Dimensions(mm): | 647W*629H*252D | |||
Weight(kg): | 45 | 45 | 45 | 45 |
Topology: | Transformerless | |||
Self consumption (night): | <1W(Night) | |||
Ingress protection: | Ip65 | |||
Noise emission(typical): | <30 dBA | |||
Cooling concept: | Natural convection | |||
Max.operation altitude:: | 4000m | |||
Designed lifetime: | >20years | |||
Relative humidity: | 0~100% | |||
Operating ambient temperature range: | -25~60ºC | |||
Grid connection standard: | EN50438, G99, AS4777, VDE0126-1-1, IEC61727,VDE4105(2018 | |||
Safty/EMC standard: | IEC62109-1/-2, AS3100, EN61000-6-1, EN61000-6-3 | |||
Features | ||||
DC connection: | MC4 | |||
AC connection: | Terminal coonectors | |||
Display: | LCD,2*20 Z. | |||
Communication connections: | 4 pins RS485 connector | |||
Monitoring: | WiFi or GPRS | |||
Warranty: | 5/10/15/20 Years |
Technical specifications
Model | Solis-40K-5G | Solis-40K-HV-5G | Solis-50K-HV-5G |
Input DC | |||
Max. DC input power(kW): | 52 | 52 | 65 |
Max. DC input voltage(V) : | 1100 | 1100 | 1100 |
Start-up voltage(V) : | 180 | 180 | 180 |
MPPT voltage range(V) : | 200-1000 | 200-1000 | 200-1000 |
Max. input current(A) : | 26+26+26+26 | 26+26+26+26 | 26+26+26+26 |
MPPT number : | 4 | 4 | 4 |
Max input strings number : | A:2; B:2; C:2; D:2 | A:2; B:2; C:2; D:2 | A:2; B:2; C:2; D:2 |
Max. Short Circuit current for each MPPT : | 39+39+39+39 | 39+39+39+39 | 39+39+39+39 |
Output AC | |||
Rated output power(kW): | 40 | 40 | 50 |
Max. apparent output power(kVA) : | 44 | 44 | 55 |
Max. output power(kW) : | 44 | 44 | 55 |
Rated grid voltage(V) : | 400 | 480 | 480 |
Rated grid frequency(Hz) : | 50/60 | 50/60 | 50/60 |
Grid frequency range(Hz) : | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 |
Operation phase : | 3/N/PE | 3/N/PE | 3/N/PE |
Rated grid output current(A) : | 57.7 | 48.1 | 60.1 |
Max. output current(A) : | 66.9 | 53 | 66.2 |
THDi (at rated output power) : | <3% | <3% | <3% |
DC injection current(mA) : | <0.5%In | <0.5%In | <0.5%In |
Power Factor (at rated output power) : | 0.8leading ... 0.8lagging | ||
Efficiency | |||
Max.efficiency: | 98.8% | 98.8% | 98.8% |
EU efficiency: | 98.3% | 98.3% | 98.3% |
MPPT efficiency : | >99.5% | >99.5% | >99.5% |
Protection | |||
DC reverse-polarity protection: | Yes | Yes | Yes |
Short circuit protection : | Yes | Yes | Yes |
Output over current protection : | Yes | Yes | Yes |
Output over voltage protection : | Yes | Yes | Yes |
Insulation resistance monitoring : | Yes | Yes | Yes |
Residual current detection : | Yes | Yes | Yes |
Surge protection : | DC Type II/ AC Type II | DC Type II/ AC Type II | DC Type II/ AC Type II |
Islanding protection : | Yes | Yes | Yes |
Temperature protection : | Yes | Yes | Yes |
Integrated DC switch : | Optional | Optional | Optional |
Anti-PID: | Optional | Optional | Optional |
General Data | |||
Dimensions(mm): | 647W*629H*252D | ||
Weight(kg) : | 45 | 45 | 45 |
Topology : | Transformerless | ||
Self consumption (night) : | <1W(Night) | ||
Ingress protection : | Ip65 | ||
Noise emission{typical} : | <30 dBA | ||
Cooling concept : | Natural convection | ||
Max.operation altitude : | 4000m | ||
Designed lifetime : | >20years | ||
Relative humidity : | 0~100% | ||
Operating ambient temperature range : | -25~60ºC | ||
Grid connection standard : | EN50438, G99, AS4777, VDE0126-1-1, IEC61727,VDE4105(2018 | ||
Safty/EMC standard: | IEC62109-1/-2, AS3100, EN61000-6-1, EN61000-6-3 | ||
Features | |||
DC connection: | MC4 | ||
AC connection : | Terminal coonectors | ||
Display : | LCD,2×20 Z. | ||
Communication connections : | 4 pins RS485 connector | ||
Monitoring : | WiFi or GPRS | ||
Warranty : | 5/10/15/20 Years |
Technical specifications
Model | Solis-80K-5G | Solis-80K-HV-5G | Solis-90K-HV-5G | Solis-100K-HV-5G | Solis-110K-HV-5G |
Input DC | |||||
Max. DC input power(kW): | 104 | 104 | 117 | 120 | 132 |
Max. DC input voltage(V): | 1100 | 1100 | 1100 | 1100 | 1100 |
Start-up voltage(V): | 200 | 200 | 180 | 180 | 180 |
MPPT voltage range(V): | 180-1000 | 180-1000 | 200-1000 | 200-1000 | 200-1000 |
Max. input current(A): | 26 | 26 | 26 | 26 | 26 |
MPPT number: | 8 | 8 | 9 | 9 | 10 |
Max input strings number: | 16 | 16 | 2 | 2 | 2 |
Max. Short Circuit current for each MPPT: | 40.6 | 40.6 | 40.6 | 40.6 | 40.6 |
Output AC | |||||
Rated output power(kW): | 80 | 80 | 90 | 100 | 110 |
Max. apparent output power(kVA): | 88 | 88 | 99 | 110 | 121 |
Max. output power(kW): | 88 | 88 | 99 | 110 | 121 |
Rated grid voltage(V): | 400 | 480 | 480 | 480 | 480 |
Operation phase: | 3/N/PE | 3/N/PE | 3/N/PE | 3/N/PE | 3/N/PE |
Max. output current(A): | 133.7 | 105.9 | 119.1 | 132.3 | 129.4 |
THDi (at rated output power): | <2% | <2% | <2% | <2% | <2% |
Power Factor (at rated output power): | 0.8leading ... 0.8lagging | ||||
Efficiency | |||||
Max.efficiency: | 99% | 99% | 99% | 99% | 99% |
EU efficiency: | 98.4% | 98.4% | 98.4% | 98.4% | 98.4% |
MPPT efficiency: | >99.5% | >99.5% | >99.5% | >99.5% | >99.5% |
Protection | |||||
Anti-islanding protection: | Yes | Yes | Yes | Yes | Yes |
DC reverse-polarity protection: | Yes | Yes | Yes | Yes | Yes |
Insulation resistance monitoring: | Yes | Yes | Yes | Yes | Yes |
Residual current detection: | Yes | Yes | Yes | Yes | Yes |
DC Surge protection: | Type replaceable | Type replaceable | Type replaceable | Type replaceable | Type replaceable |
AC Surge protection: | Type | Yes | Yes | Yes | Yes |
Grid monitoring: | Yes | Yes | Yes | Yes | Yes |
Strings Monitoring: | Yes | Yes | Yes | Yes | Yes |
I/V Curve scanning: | Yes | Yes | Yes | Yes | Yes |
Anti-PID function: | Yes | Yes | Yes | Yes | Yes |
AFCI fuction: | Optional | Optional | Optional | Optional | Optional |
General Data | |||||
Dimensins(mm): | 1050W*567H*286.5D | ||||
Weight(kg): | 75 | ||||
Topology: | Transformerless | ||||
Self consumption (night): | <2W(Night) | ||||
Ingress protection: | Ip65 | ||||
Noise emission(typical): | <55 dBA | ||||
Cooling concept: | Fan cooling | ||||
Max.operation altitude:: | 4000m(>2000m derating) | ||||
Designed lifetime: | >20years | ||||
Designed lifetime: | 0~100% | ||||
Operating ambient temperature range: | -25~60ºC | ||||
Grid connection standard: | EN50549, G99, AS4777, VDE0126-1-1, IEC61727, VDE4105 | ||||
Safty/EMC standard: | IEC62109-1/-2, NB/T 32004,EN61000-6-1, EN61000-6-3 | ||||
Features | |||||
DC switch: | Integrated | ||||
DC connection: | MC4 | ||||
AC connection: | OT Terminal connectors | ||||
DRM function: | Yes | ||||
Display: | LCD,2*20 Z. | ||||
OTA update: | Yes | ||||
Communication connections: | 1*4pin RS485,2*RJ45,1*DRM | ||||
Communication: | RS485/ WLAN(provide);PLC/Wifi/GPRS(optional) | ||||
Monitoring: | WiFi or GPRS | ||||
Warranty: | 5/10/15/20 Years |
Our Projects
Contact
Supply Ability
--
Packaging and Shipping
Lead time
--
Port
--
Packaging details
--
Comments
Welcome to zddshop comments! Please keep conversations courteous and on-topic. To fosterproductive and respectful conversations,
you may see comments from our Community Managers.
Sign up to post
Show More Comments